Variac Drawings   

ISEinc.com  Variac.com  |   Literature & Documentation  |

  Part Number Cross Reference
 

 Variac Selector

 Portable Variacs with Cord Plug Receptacle

 Portable Variacs with Digital Volt and/or Ammeters

 Single Phase Variacs, 120VAC Input; 0-140VAC Output

 Single Phase Variacs, 120VAC Input; 0-280VAC Output

 Single Phase Variacs, 240VAC Input; 0-280VAC Output

 Single Phase Variacs, 240VAC Input; 0-560VAC Output

 Single Phase Variacs, 480VAC Input; 0-560VAC Output

 Three Phase Variacs, 240VAC Input; 0-280VAC Output

 Three Phase Variacs, 240VAC Input; 0-560VAC Output

 Three Phase Variacs, 480VAC Input; 0-560VAC Output

 Home

 Product List

 
Temperature & Process Controls

 Digital Panel Meters

 Pressure Transducers & Indicators

 Timers & Counters

 Data Loggers

 Recorders

 Variac Variable Transformers

 SCR Power Controls

 Voltage Regulators & UPS Systems

 Thermocouples

 Electric Heating Elements

 Literature List

Web Store

Repair and Calibration

Technical Data & Calculators

 

Get Acrobat Reader

Staco Variable Transformers

Return to Transformer Selector

(Click on P/N for more detailed specifications)

Three Phase Wye Phase Voltage Doublers 240V Input 0-560V Outputs

Manually Operated P/N Motor Driven P/N

Input

Volts

Phase Hertz

Output

Volts

Current

Rating to 300V

Current

Rating at 430V

Current

Rating at 560V

Features
1020B-3 M1020B-3 240 3 PH 60 0-560 3.5A 2.0A 1.5A 3-Ganged Unit, Add 'CT' Suffix for Cased version
1520-3 M1520-3 240 3 PH 60 0-560 9.5A 5.4A 4.1A 3-Ganged Unit, Add 'CT' Suffix for Cased version
2520-3 M2520-3 240 3 PH 60 0-560 10A 5.7A 4.4A 3-Ganged Unit, Add 'CT' Suffix for Cased version
5021-3 M5021-3 240 3 PH 60 0-560 28A 16A 12.3A 3-Ganged Unit, Add 'E' Suffix for Cased version
6020-3 M6020-3 240 3 PH 60 0-560 35A 20A 15.4A 3-Ganged Unit, Add 'E' Suffix for Cased version
5021-6Y M5021-6Y 240 3 PH 60 0-560 56A 32A 24.6A 6-Ganged Unit; Add 'E' Suffix for Enclosed version
6020-6Y M6020-6Y 240 3 PH 60 0-560 70A 40A 30.8A 6-Ganged Unit, Add 'E' Suffix for Cased version
5021-9Y M5021-9Y 240 3 PH 60 0-560 84A 48A 37A 9-Ganged Unit; Add 'E' Suffix for Enclosed version
6020-9Y M6020-9Y 240 3 PH 60 0-560 105A 60A 46A 9-Ganged Unit, Add 'E' Suffix for Cased version
M5021-12Y 240 3 PH 60 0-560 112A 64A 49A 12-Ganged Unit; Add 'E' Suffix for Enclosed version
M6020-12Y 240 3 PH 60 0-560 140A 80A 62A 12-Ganged Unit, Add 'E' Suffix for Cased version
M5021-15Y 240 3 PH 60 0-560 168A 96A 74A 15-Ganged Unit; Add 'E' Suffix for Enclosed version
M6020-15Y 240 3 PH 60 0-560 175A 100A 77A 15-Ganged Unit, Add 'E' Suffix for Cased version
M5021-21Y 240 3 PH 60 0-560 196A 112A 86A 21-Ganged Unit; Add 'E' Suffix for Enclosed version
M6020-18Y 240 3 PH 60 0-560 210A 120A 92A 18-Ganged Unit, Add 'E' Suffix for Cased version
M5021-24Y 240 3 PH 60 0-560 224A 128A 99A 24-Ganged Unit; Add 'E' Suffix for Enclosed version
M6020-21Y 240 3 PH 60 0-560 245A 140A 108A 21-Ganged Unit, Add 'E' Suffix for Cased version
M5021-27Y 240 3 PH 60 0-560 252A 144A 111A 27-Ganged Unit; Add 'E' Suffix for Enclosed version
M6020-24Y 240 3 PH 60 0-560 280A 160A 123A 24-Ganged Unit, Add 'E' Suffix for Cased version
M6020-27Y 240 3 PH 60 0-560 315A 180A 139A 27-Ganged Unit; Add 'E' Suffix for Enclosed version

 

request.jpg (10520 bytes)Click on this link to request further variable transformer information

Important Notes:

CURRENT RATING TERMINOLOGY: To permit maximum utilization of STACO Variable Transformers, output ratings are given for both constant current and constant impedance loads. All current ratings are based on continuous use at ambient temperatures to 122 F (50 C).  Use derating curve for higher ambients.  Short duration overloads to 10 times transformer rating are possible.  See graph for acceptable limits.

CONSTANT CURRENT RATING: Output current that can be carried regardless of output voltage setting. (Reduce, for output above 125% of input voltage, on voltage doubler connection. See Graph)

CONSTANT IMPEDANCE RATING: Output current that can be carried with loads such as incandescent lamps or resistance heaters in which the current drawn is approximately proportional to the applied voltage, increasing to maximum current at line voltage. This rating applies only to applications where maximum output voltage is limited to line voltage.

THREE PHASE CONNECTED TRANSFORMERS: If ganged units are used in a system that ordinarily has a common neutral or ground between source and load, the neutral or ground must be connected to the common terminals of the variable transformer assembly. If the system has no neutral, the load must be balanced or the transformers will be damaged.

OPERATION AT HIGHER FREQUENCIES: All Staco variable transformers are designed for operation at 60 or 50/60 Hz.  Most models can also properly operate with input frequencies to 2000 Hz.  Some models output ratings must be derated at higher frequencies. See derating table for details.

 

 
   
 
 
 

[HRule Image]

Below are some links to our most popular web pages (click on the graphic to follow the link). For a complete listing click Products.

 

HOME

PRODUCTS

 

SEARCH

FEEDBACK

Track a shipment from ISE     Transit times for UPS Ground from ISE 

[HRule Image]

 

   

Headquarters
10100 Royalton Rd.,  Cleveland, OH  44133  USA
Phone: (440) 237-3200  Fax: (440) 237-1744
Email ISE Cleveland
 
Toledo Area Office
417 Tomahawk Drive,  Maumee, Oh 43537
Phone: 419-893-3330 - FAX: 419-893-2151
Email ISE Toledo  
 

ISE, Inc. Privacy Policy

Click for Cleveland, Ohio Forecast

Copyright © 2008 ISE, Inc.  All rights reserved.